By RichPen

RichPen Back Lever 29714

Regular price $3.00 USD
Regular price Sale price $3.00 USD
Shipping calculated at checkout.
Brand: RichPen
Availability: Low stock
SKU: 29714
Regular price $3.00 USD
Regular price Sale price $3.00 USD
RichPen Airbrush Replacement Part

RichPen Back Lever 29714 for Apollo 112A and 112B Airbrushes

Replace a worn, damaged, or missing back lever in a compatible RichPen Apollo airbrush with the RichPen Back Lever 29714. This model-specific trigger component is listed for the RichPen Apollo 112A and Apollo 112B airbrushes.

Key Features

  • Replacement back lever for compatible RichPen Apollo airbrush models.
  • Compatible with Apollo 112A and Apollo 112B airbrushes.
  • Manufacturer SKU 29714 provides an exact reference for selecting the correct replacement component.
  • Part of the trigger and needle-control assembly inside the compatible airbrush.
  • Individual replacement component allows the back lever to be serviced without replacing the complete airbrush.
  • This listing includes the back lever only, not the finger lever, needle, trigger pin, spring components, or complete airbrush.

Product Specifications

Brand RichPen
Product Name Back Lever
Manufacturer SKU 29714
Product Type Replacement airbrush back lever
Compatible Series RichPen Apollo
Compatible Models RichPen Apollo 112A and Apollo 112B
Installation Area Trigger and needle-control assembly
Included Component 1 replacement back lever
Complete Airbrush Included No

Compatible RichPen Apollo Airbrushes

The RichPen Back Lever 29714 is listed for the RichPen Apollo 112A 0.2mm gravity-feed airbrush and the RichPen Apollo 112B 0.2mm gravity-feed airbrush.

Confirm both the airbrush model and manufacturer SKU before ordering. Internal trigger components can appear similar while using different dimensions, shapes, or fitting arrangements.

Part of the Trigger and Needle Assembly

The back lever is an internal component located behind the finger lever within the compatible airbrush. It works with the trigger and needle assembly during normal operation.

Correct positioning and alignment are important for smooth trigger movement and consistent needle response.

When the Back Lever May Need Replacement

  • The original back lever is missing after maintenance.
  • The component is bent, cracked, worn, or physically damaged.
  • The lever does not remain correctly positioned in the trigger assembly.
  • Trigger or needle movement remains inconsistent after cleaning.
  • The component no longer aligns with the finger lever or needle assembly.
  • Correct reassembly does not restore normal airbrush operation.

Product Notice: This listing includes one RichPen Back Lever 29714 only. The complete airbrush, finger lever, trigger pin, needle, spring components, valve parts, and other replacement components are not included.

Compatibility Notice: Compatibility is confirmed for the RichPen Apollo 112A and Apollo 112B. Do not select a replacement trigger component based only on visual similarity.

Installation and Inspection Guidance

  • Confirm that the airbrush is a RichPen Apollo 112A or 112B.
  • Remove the needle carefully before disassembling the trigger area.
  • Work over a clean surface so small parts are not lost.
  • Inspect the finger lever and nearby trigger components for damage.
  • Install the back lever in the correct position and orientation.
  • Do not force, bend, or modify the replacement component.
  • Confirm smooth trigger and needle movement after reassembly.
  • Test the airbrush with cleaner or water before spraying paint.

Inspect Related Trigger Components

When replacing the back lever, inspect the finger lever, trigger pin, needle support, spring components, valve plunger, and surrounding trigger area for wear, dried paint, or physical damage.

A damaged or incorrectly installed related component may continue to affect trigger movement after the replacement back lever is installed.

Cleaning and Maintenance

Remove dried paint and residue from the trigger area using an airbrush cleaner compatible with the paint being removed. Avoid excessive force or abrasive tools on the lever and surrounding internal components.

Allow cleaned parts to dry before reassembly. Confirm that the trigger and needle move freely before using the airbrush with paint.

Frequently Asked Questions

Which RichPen airbrushes use Back Lever 29714?
The RichPen Back Lever 29714 is listed for the Apollo 112A and Apollo 112B airbrushes.
What does the back lever do?
It is an internal trigger component positioned behind the finger lever and works with the compatible needle-control assembly.
Is this listing for a complete RichPen airbrush?
No. This listing includes one replacement back lever only. The complete airbrush and other trigger components are not included.
Does Back Lever 29714 include the finger lever?
No. The finger lever is a separate replacement component and is not included with the back lever.
Can this lever be used with another RichPen model?
Compatibility is confirmed only for the RichPen Apollo 112A and 112B. Other airbrush models may use components with different shapes or dimensions.
What can cause poor trigger movement?
Dried paint, a bent needle, incorrectly installed trigger parts, damaged lever components, or problems within the air valve assembly may cause stiff or inconsistent trigger movement.
Should the airbrush be tested after replacement?
Yes. Confirm smooth trigger and needle movement, then test the airbrush with cleaner or water before spraying paint.

View the Compatible RichPen Airbrushes

Review the RichPen Apollo 112A airbrush or compare it with the RichPen Apollo 112B airbrush before selecting this replacement back lever.