1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
-
Save $0.70 USD
Vendor:IwataIwata QuickFit Quick Disconnect Set
Regular price $13.50 USDRegular price$14.20 USD-$0.70 USD Sale price $13.50 USD -
Vendor:IwataIwata QuickFit Quick Disconnect Airbrush Adaptor
Regular price $8.91 USDRegular priceSale price $8.91 USD -
Vendor:IwataIwata Needle Crown Cap I1050
Regular price $16.40 USDRegular priceSale price $16.40 USD -
Vendor:IwataIwata Needle Chucking Nut I1202
Regular price $5.44 USDRegular priceSale price $5.44 USD -
-
-
Vendor:IwataIwata Air Valve Spring I5104
Regular price $8.30 USDRegular priceSale price $8.30 USD -
Vendor:IwataIwata Air Valve O-Ring I5801
Regular price $8.81 USDRegular priceSale price $8.81 USD -
Sold out
-
Vendor:IwataIwata Nozzle Cap (E3) I6022
Regular price $12.47 USDRegular priceSale price $12.47 USD -
-
-
Vendor:IwataIwata Joint/Handle O-Ring I6051
Regular price $5.44 USDRegular priceSale price $5.44 USD -
Vendor:IwataIwata Air Valve Guide I6081
Regular price $8.81 USDRegular priceSale price $8.81 USD -
-
Vendor:IwataIwata Air Valve Guide Screw I6111
Regular price $5.44 USDRegular priceSale price $5.44 USD -
Vendor:IwataIwata Main Lever / Trigger I6121
Regular price $11.25 USDRegular priceSale price $11.25 USD -
-
Vendor:IwataIwata Gravity Feed Cup Lid (0.24 / 7ml) I6181
Regular price $11.80 USDRegular priceSale price $11.80 USD -
Vendor:IwataIwata Handle with Single Cut Out I6191
Regular price $23.62 USDRegular priceSale price $23.62 USD -
Vendor:IwataIwata Needle Chucking Guide I7151
Regular price $11.81 USDRegular priceSale price $11.81 USD -
Sold out
Vendor:IwataIwata Needle Packing Screw Set with PTFE Packing (H3, C5, R5) I7251
Regular price $8.30 USDRegular priceSale price $8.30 USD -
Vendor:IwataIwata Needle Spring Guide I7701
Regular price $9.57 USDRegular priceSale price $9.57 USD -
Sold out
Vendor:IwataIWATA Gravity Feed Cup Lid (0.24 oz / 7 ml)
Regular price $15.75 USDRegular priceSale price $15.75 USD -
Vendor:IwataIWATA Rapid Access Handle/Needle Grip Set
Regular price $48.15 USDRegular priceSale price $48.15 USD
Iwata Eclipse HP-CS Airbrush Parts & Replacement Components
Find Iwata Eclipse HP-CS parts for maintenance, repair, and model-specific component replacement. This collection includes needles, nozzles, needle caps, nozzle caps, head components, air-valve parts, O-rings, springs, needle-packing components, trigger parts, gravity-feed cup components, handles, QuickFit accessories, and other service parts for the Eclipse HP-CS airbrush.
Iwata Eclipse HP-CS Replacement Parts
The Eclipse HP-CS uses a combination of front-end, airflow, needle-control, trigger, gravity-feed, and rear-handle components. If a part becomes worn, damaged, or difficult to clean, replacing the correct component can help return the airbrush to normal operation.
Always compare the replacement-part name, Iwata part number, and listed compatibility with the Iwata Eclipse HP-CS before installation.
- Needles and nozzles: Components involved in paint delivery and spray formation.
- Needle, nozzle, crown, and head caps: Front-end parts surrounding and protecting the needle and nozzle assembly.
- Air-valve components: Valve parts, guides, guide screws, springs, and O-rings used within the airflow system.
- Needle-control components: Chucking guides, chucking nuts, springs, spring guides, and related internal parts.
- Trigger and lever components: Main lever and related parts used during normal airbrush control.
- Cup and rear components: Gravity-feed cup lids, preset handles, standard handles, and compatible rear-access components.
HP-CS Needle, Nozzle & Front-End Parts
The needle and nozzle assembly is an important part of paint delivery and spray formation. Bent needles, damaged nozzles, dried paint, or worn front-end components can affect paint flow and the way the airbrush sprays.
Before replacing a component, clean and inspect the front assembly. Confirm that the needle, nozzle, needle cap, nozzle cap, crown cap, and head cap are intended for the Eclipse HP-CS configuration.
- Needle: Inspect the needle tip for bending, wear, or visible damage.
- Nozzle: Check the opening and seating area for dried paint, wear, or physical damage.
- Needle crown cap: Helps protect the exposed front portion of the needle.
- Needle, nozzle, and head caps: Match these front-end components by model and part number.
Iwata Eclipse HP-CS Air-Valve Components
This collection includes several parts associated with the HP-CS airflow system, including air-valve components, valve guides, guide screws, valve springs, and O-rings.
If airflow or trigger response changes, clean and inspect the airbrush before assuming a component requires replacement. Dried material, worn seals, incorrect assembly, or damaged internal parts can affect airflow.
HP-CS Trigger, Needle Spring & Chucking Parts
Trigger and needle movement rely on several connected internal components. These include the main lever, needle chucking guide, needle chucking nut, needle spring, and needle spring guide.
- Main lever / trigger: Forms part of the HP-CS trigger-control system.
- Needle chucking guide: Supports the rear needle-control assembly.
- Needle chucking nut: Secures the needle within the internal movement system.
- Needle spring and spring guide: Support needle positioning and return during operation.
If movement becomes stiff or inconsistent, inspect these areas for dried paint, contamination, incorrect installation, or visible wear.
HP-CS O-Rings & PTFE Needle Packing
O-rings and packing components are used at specific locations within the airbrush to support sealing around airflow, paint, and moving internal assemblies.
The current collection includes compatible air-valve O-rings, joint or handle O-rings, and PTFE needle-packing components. Match each replacement to its intended location and Iwata part number before installation.
Gravity-Feed Cup & Lid Components
The Iwata Eclipse HP-CS uses a top-mounted gravity-feed paint cup. The current collection includes compatible gravity-feed cup lids and related cup components for maintenance or replacement.
Check the cup size and lid configuration before ordering because similar Iwata cup components can vary between airbrush models.
Preset Handles & Rear HP-CS Components
Compatible rear components in this collection include preset-handle and single-cut-out handle configurations, along with a Rapid Access handle or needle-grip set.
A preset handle can provide a mechanical limit for rearward needle movement. Compatible rear-access components can also provide another way to reach or handle the needle during maintenance.
Review the individual product information before changing rear components to confirm HP-CS compatibility.
Iwata QuickFit Quick Disconnect Parts
The collection also includes Iwata QuickFit components, including a quick-disconnect set and an airbrush adapter.
Quick-disconnect fittings can make it easier to attach or remove an airbrush from a compatible air hose setup. Check the fitting, connection type, and related equipment before changing air-line components.
Using the Iwata Eclipse HP-CS Parts Diagram
The Iwata Eclipse HP-CS parts diagram shown on this collection page can help identify the location of individual replacement components before maintenance or repair.
Use the diagram together with the product title and Iwata part number when identifying needles, nozzles, caps, valve components, trigger parts, handles, springs, seals, and other internal pieces.
Do not rely on appearance alone when choosing a replacement. Different Iwata airbrush components can look similar while using different dimensions or applications.
How to Find the Correct Iwata Eclipse HP-CS Part
Start with the exact airbrush model and then compare the replacement component name, Iwata part number, dimensions, and compatibility information shown on the individual product listing.
- Confirm HP-CS compatibility: Make sure the replacement component is listed for the Iwata Eclipse HP-CS.
- Check the Iwata part number: Use the part number as a reference rather than relying only on the appearance of the component.
- Match needle and nozzle components carefully: Front-end components should belong to the correct HP-CS setup.
- Review air-valve compatibility: Valve components can differ between Iwata models and series.
- Confirm O-ring and packing location: Match sealing components to their intended internal position.
- Check cup and rear-handle configuration: Compare the size and component style before replacement.
Iwata Eclipse HP-CS Cleaning & Maintenance
Routine cleaning helps reduce dried-paint buildup around the needle, nozzle, gravity-feed cup, paint path, trigger area, and other moving components. Handle small front-end and internal parts carefully during removal and reassembly.
- Flush the paint path after painting sessions.
- Clean the gravity-feed cup and cup lid after use.
- Clean the needle carefully before reinstalling it.
- Inspect the nozzle before assuming replacement is required.
- Check air-valve components if airflow becomes irregular.
- Inspect O-rings and needle packing if leaks appear.
- Check springs and chucking components if needle movement changes.
- Reassemble internal components in the correct order and orientation.
Related Iwata Eclipse & Replacement Parts
Replacement components for additional Iwata models can be found in the Iwata Airbrush Parts collection .
Compare complete HP-CS, HP-BS, HP-BCS, Eclipse Takumi, value-set, and related configurations in the Iwata Eclipse Airbrushes collection .
Additional Iwata airbrush series are available in the Iwata Airbrushes collection .